To verify always consult the manufacturers current documentation.
| Heat Pump Size |
Unit |
10 |
13 |
16 |
| Heating performance data to EN 14511 (A2/W35) |
| Rated heating output | kW | 5.8 | 6.7 | 7.6 |
| Power consumption | kW | 1.41 | 1.76 | 2.00 |
| Coefficient of performance ε in heating mode (COP) | - | 4.1 | 3.8 | 3.8 |
| Output control | kW | 2.2 to 11.0 | 2.6 to 12.3 | 3.0 to 13.7 |
| Heating performance data to EN 14511 (A7/W35, 5 K spread) |
| Rated heating output | kW | 7.4 | 8.1 | 9.1 |
| Fan speed | rpm | 430 | 440 | 567 |
| Air flow rate | m³/h | 4045 | 4188 | 5393 |
| Power consumption | kW | 1.42 | 1.59 | 1.82 |
| Coefficient of performance ε in heating mode (COP) | - | 5.2 | 5.1 | 5.0 |
| Output control | kW | 2.6 to 12.0 | 3.0 to 13.4 | 3.3 to 14.9 |
| Heating performance data to EN 14511 (A−7/W35) |
| Rated heating output | kW | 10.0 | 11.1 | 12.4 |
| Power consumption | kW | 3.23 | 3.96 | 4.4 |
| Coefficient of performance ε in heating mode (COP) | - | 3.0 | 2.8 | 2.8 |
| Heating performance data to EN 14511 (A−7/W55) |
| Rated heating output | kW | 9.2 | 10.6 | 11.8 |
| Power consumption | kW | 4.79 | 5.12 | 5.28 |
| Coefficient of performance ε in heating mode (COP) | - | 1.9 | 2.1 | 2.2 |
| Heating performance data to Commission Regulation (EU) No 813/2013 (average climatic conditions) |
| Low temperature application (W35) – Energy efficiency ηs | % | 199 | 194 | 188 |
| Low temperature application (W35) – Rated heating output Prated | kW | 9.8 | 12.4 | 13.67 |
| Low temperature application (W35) – Seasonal coefficient of performance (SCOP) | - | 5.06 | 4.93 | 4.78 |
| Medium temperature application (W55) – Energy efficiency ηs | % | 156 | 155 | 150 |
| Medium temperature application (W55) – Rated heating output Prated | kW | 9.37 | 12.1 | 13.37 |
| Medium temperature application (W55) – Seasonal coefficient of performance (SCOP) | - | 3.97 | 3.95 | 3.82 |
| Energy efficiency class to Commission Regulation (EU) No 813/2013 (heating, average climatic conditions) |
| Low temperature application (W35) (D→A+++) | - | A+++ | A+++ | A+++ |
| Medium temperature application (W55) (D→A+++) | - | A+++ | A+++ | A+++ |
| Cooling performance data to EN 14511 (A35/W7) |
| Rated cooling capacity | kW | 3.90 | 5.15 | 6.3 |
| Fan speed | rpm | 550 | 550 | 550 |
| Power consumption | kW | 1.18 | 1.29 | 1.85 |
| Coefficient of performance in cooling mode (EER) | - | 3.30 | 4.00 | 3.40 |
| Output control | kW | 3.9 to 7.2 | 4.2 to 8.0 | 4.5 to 8.7 |
| Cooling performance data, average climatic conditions (A35/W7) |
| Rated cooling capacity Prated | kW | 6.90 | 8.11 | 8.93 |
| Seasonal cooling energy efficiency ratio (SEER) | - | 3.60 | 4.71 | 4.10 |
| Cooling performance data to EN 14511 (A35/W18) |
| Rated cooling capacity | kW | 9.50 | 11.20 | 13.30 |
| Power consumption | kW | 2.10 | 2.70 | 3.60 |
| Coefficient of performance in cooling mode (EER) | - | 4.50 | 4.10 | 3.70 |
| Output control | kW | 6.5 to 13.4 | 6.8 to 14.7 | 7.1 to 16.0 |
| Cooling performance data, average climatic conditions (A35/W18) |
| Rated cooling capacity Prated | kW | 9.81 | 11.51 | 13.32 |
| Seasonal cooling energy efficiency ratio (SEER) | - | 7.20 | 6.70 | 6.30 |
| Air inlet temperature |
| Cooling mode – Min. | °C | 15 | 15 | 15 |
| Cooling mode – Max. | °C | 45 | 45 | 45 |
| Heating mode – Min. | °C | -20 | -20 | -20 |
| Heating mode – Max. | °C | 40 | 40 | 40 |
| Heating water (secondary circuit) |
| Capacity excl. expansion vessel | l | 18 | 18 | 18 |
| Heat pump circuit minimum flow rate (defrosting) | l/h | 1000 | 1000 | 1000 |
| Max. flow temperature | °C | 70 | 70 | 70 |
| Outdoor unit electrical values |
| Rated voltage | - | 3/N/PE 400 V~ / 50 Hz |
| Max. operating current | A | 12 | 12 | 12 |
| Cos φ | - | 0.96 | 0.96 | 0.96 |
| Compressor starting current, inverter controlled | A | < 10 | < 10 | < 10 |
| Compressor starting current with stalled armature | A | < 10 | < 10 | < 10 |
| Fuse protection | - | B16A | B16A | B16A |
| IP rating | - | IPX4 | IPX4 | IPX4 |
| Indoor unit electrical values |
| PCB – Rated voltage | - | 1/N/PE 230 V~ / 50 Hz |
| PCB – Power supply fuse protection | - | 1 x B16A | 1 x B16A | 1 x B16A |
| PCB – Internal fuse protection | - | 6.3 A H (slow) / 250 V~ |
| Instantaneous heating water heater |
| Rated voltage | - | 3/N/PE 400 V~ / 50 Hz |
| Heating output – Max. | kW | 8 | 8 | 8 |
| Heating output – Stage 1 | kW | 2.4 | 2.4 | 2.4 |
| Heating output – Stage 2 | kW | 2.4 | 2.4 | 2.4 |
| Heating output – Stage 3 | kW | 3.2 | 3.2 | 3.2 |
| Power supply fuse protection | - | 3 x B16A | 3 x B16A | 3 x B16A |
| Max. power consumption |
| Outdoor unit – Fan | W | 2 x 140 | 2 x 140 | 2 x 140 |
| Outdoor unit – Total | kW | 4.8 | 5.4 | 5.4 |
| Indoor unit – Integral secondary pump/heating circuit pump, heating/cooling circuit 1 (PWM) | W | 60 | 60 | 60 |
| Indoor unit – Energy efficiency index EEI of the circulation pumps | - | ≤ 0.2 | ≤ 0.2 | ≤ 0.2 |
| Indoor unit – Control unit/PCB | W | 5 | 5 | 5 |
| Indoor unit – Max. connected load, function components 230 V~ | W | 1000 | 1000 | 1000 |
| Mobile data transfer |
| WiFi |
| Transmission standard | - | IEEE 802.11 b/g/n | IEEE 802.11 b/g/n | IEEE 802.11 b/g/n |
| Frequency band | MHz | 2400 to 2483.5 | 2400 to 2483.5 | 2400 to 2483.5 |
| Max. transmission power | dBm | +15 | +15 | +15 |
| Low power radio |
| Transmission standard | - | IEEE 802.15.4 | IEEE 802.15.4 | IEEE 802.15.4 |
| Frequency band | MHz | 2400 to 2483.5 | 2400 to 2483.5 | 2400 to 2483.5 |
| Max. transmission power | dBm | +6 | +6 | +6 |
| Refrigerant circuit |
| Refrigerant | - | R290 | R290 | R290 |
| Safety group | - | A3 | A3 | A3 |
| Charge weight | kg | 2 | 2 | 2 |
| Global warming potential (GWP) | - | 0.02 | 0.02 | 0.02 |
| CO2 equivalent | t | 0.00004 | 0.00004 | 0.00004 |
| Compressor (hermetically sealed) – Type | - | Twin rotary | Twin rotary | Twin rotary |
| Oil in compressor – Type | - | HAF68 | HAF68 | HAF68 |
| Oil volume in compressor | l | 1.150 ± 0.020 | 1.150 ± 0.020 | 1.150 ± 0.020 |
| Permissible operating pressure |
| High pressure side | bar | 30.3 | 30.3 | 30.3 |
| High pressure side | MPa | 3.03 | 3.03 | 3.03 |
| Low pressure side | bar | 30.3 | 30.3 | 30.3 |
| Low pressure side | MPa | 3.03 | 3.03 | 3.03 |
| Outdoor unit dimensions |
| Total length | mm | 600 | 600 | 600 |
| Total width | mm | 1144 | 1144 | 1144 |
| Total height | mm | 1382 | 1382 | 1382 |
| Indoor unit dimensions |
| Total length | mm | 360 | 360 | 360 |
| Total width | mm | 450 | 450 | 450 |
| Total height | mm | 920 | 920 | 920 |
| Total weight |
| Indoor unit – Empty | kg | 47 | 47 | 47 |
| Indoor unit – Filled (max.) | kg | 74 | 74 | 74 |
| Outdoor unit | kg | 197 | 197 | 197 |
| Permissible operating pressure on the secondary side |
| Permissible operating pressure on the secondary side | bar | 3 | 3 | 3 |
| Permissible operating pressure on the secondary side | MPa | 0.3 | 0.3 | 0.3 |
| Connections to indoor unit without installation aid |
| Heating water flow/return, heating/cooling circuit or external buffer cylinder | mm | Cu 28 x 1.0 | Cu 28 x 1.0 | Cu 28 x 1.0 |
| Heating water flow/return, DHW cylinder | mm | Cu 22 x 1.0 | Cu 22 x 1.0 | Cu 22 x 1.0 |
| Heating water flow/return, outdoor unit | mm | Cu 28 x 1.0 | Cu 28 x 1.0 | Cu 28 x 1.0 |
| Length of connection line, indoor — outdoor unit (e.g. Quattro connection line) |
| Length of connection line | m | 5 to 20 | 5 to 20 | 5 to 20 |
| Sound power at rated heating output (reference DIN EN 12102-1:2023 and DIN EN ISO 3744:2011 in ErP point C to DIN EN 14825; operating conditions A7/W55) |
| Indoor unit – ErP | dB(A) | 40 | 40 | 40 |
| Outdoor unit – ErP | dB(A) | 53 | 54 | 55 |
| Outdoor unit – Max. | dB(A) | 61 | 61 | 66 |