Vitocal 150-A Standard (A04 230V V105) 4kW

£11,035.20 inc VAT
1 In Stock

Vitocal 150-A (A04 230V V105) 4 kW

Up to 70 °C flow temperature

Heat pump with electric drive in monoblock design with outdoor and indoor unit.

Quick facts

  • Monobloc heat pump: indoor + outdoor unit
  • Up to 70 °C flow temperature (subject to system design)
  • Natural refrigerant R290 (low GWP)
  • Integral WiFi; system monitoring via ViCare (end user) and ViGuide (installer)

Product features – for space heating, cooling and domestic hot water (DHW) heating

  • For space heating, cooling and domestic hot water (DHW) heating
  • Monobloc indoor unit with heat pump control unit
  • High-efficiency circulation pump for the secondary circuit
  • Integral 4/3-way valve and safety assembly
  • Integral instantaneous heating water heater
  • Integral buffer cylinder and overflow valve

Advantages at a glance – high COP, up to 70 °C flow temp, R290, quiet operation
  • Low running costs thanks to high COP (coefficient of performance) to EN 14511: up to 5.2 at A7/W35 (depending on operating conditions)
  • Output control and DC inverter for high efficiency in partial load operation
  • Maximum flow temperature of up to 70 °C at an outside temperature of −10 °C (subject to system design)
  • Self-optimising control of the flow rate via Viessmann Hydro AutoControl
  • Environmentally responsible, natural refrigerant R290 with a particularly low GWP (global warming potential)
  • Convenient reversible design for heating and cooling (availability subject to system configuration)
  • Reduced sound emissions thanks to Advanced Acoustic Design (AAD)
  • Web-enabled via integral WiFi
  • Guided commissioning via ViGuide
  • Individual room control with components from ViCare Smart Climate

Key specifications - permissible operating pressure (heating water): 3 bar (0.3 MPa)
  • Permissible operating pressure (heating water): 3 bar (0.3 MPa)
  • Colour of indoor unit: Vitopearlwhite
  • Colour of outdoor unit: Vitosilver

Heat pump control unit - for weather-compensated mode
  • 7-inch colour touchscreen with energy cockpit
  • WiFi hotspot for local service without internet connection
  • Internet connection via WiFi
  • Control of a DHW circulation pump
  • Control of an instantaneous heating water heater
  • Active cooling control function
  • Integral energy statement
  • Setting of low-noise mode for the outdoor unit
  • Optimised energy management, e.g. in conjunction with photovoltaic system, power storage system
  • Display of energy flows in the ViCare app and ViGuide

Mobile applications - Communication technology

ViCare app – mobile application for system users
  • Mobile operation of the heating system for room heating and DHW heating, power storage units and ventilation systems
  • Assistance functions and fault display with option for direct connection to the contractor for service requests
  • For more information on system requirements and ViCare app registration and usage, see Vicare App Guide
  • Download:

Vitocal 150-A Standard (A04 230V V 105) 4kW   Vitocal 150-A Standard (A04 230V V 105) 4kW

ViGuide – mobile applications for trade partners
  • Service and maintenance with ViGuide for optimising workflows in operation, for the Viessmann trade partner
  • Ensures customer-friendly online services for the system user, provided they have enabled service via the ViCare app
  • Straightforward and efficient commissioning of heat generators with integral communication module, power storage units and ventilation systems, performed by heating contractors using ViGuide
  • In addition to the free version, ViGuide Plus and ViGuide Pro are also available as paid-for versions with additional analysis, remote maintenance and optimisation functions
  • For more information on system requirements and ViGuide registration and usage, see ViGuide App Guide
  • Download:

Vitocal 150-A Standard (A04 230V V 105) 4kW   Vitocal 150-A Standard (A04 230V V 105) 4kW

Standard delivery - Indoor and Outdoor units

IDU-A indoor unit

  • Integral 4/3-way valve for room heating, DHW heating and bypass
  • Integral high-efficiency circulation pump for the secondary circuit
  • Integral instantaneous heating water heater
  • Integral 16 l buffer cylinder
  • Integral safety valve and digital pressure gauge
  • Weather-compensated heat pump control unit with outside temperature sensor
  • Integrated flow rate measurement
  • Wall mounting bracket
  • 12 l diaphragm expansion vessel

ODU 150-A outdoor unit

  • Inverter-controlled compressor
  • 4-way diverter valve
  • Electronic expansion valve
  • Evaporator and condenser
  • EC fan
  • Factory-filled with refrigerant R290
  • Heating water filter upstream of condenser
  • Transport aid for outdoor unit
  • Integral fan ring heater and electric ribbon heater for the condensate pan

Important

  • Specifications and features may vary by model and configuration. All performance figures are subject to system design, installation conditions and operating parameters.
  • For the indoor units, a Basic or Comfort pre-plumbing jig must be added to the order; see Accessories tab.
  • The heat pumps must be commissioned by Viessmann Technical Service or a specialist heat pump contractor trained by Viessmann.
  • To operate multiple regulated heating/cooling circuits downstream of the heating water buffer cylinder, a separate heating/cooling water buffer cylinder is required.
  • Extensions/accessories are required for the heating/cooling circuits with mixer and optimisation of self-consumption: see Accessories tab.

Vitocal 150-A – Specification Tables (230 V) – 04 / 06 / 08 kW

To verify these details, always consult the manufacturer’s current documentation.

Item Unit 04 06 08
Heating performance data to EN 14511 (A2/W35)
Rated heating outputkW2.53.14.0
Fan speedrpm376401447
Power consumptionkW0.660.821.08
Coefficient of performance ε in heating mode (COP)3.83.83.7
Output controlkW1.8 to 4.51.8 to 6.01.8 to 6.8
Heating performance data to EN 14511 (A7/W35, 5 K spread)
Rated heating outputkW4.04.85.6
Fan speedrpm412443482
Air flow ratem³/h181319542125
Power consumptionkW0.800.981.19
Coefficient of performance ε in heating mode (COP)5.04.94.7
Output controlkW2.1 to 4.02.1 to 6.02.1 to 8.0
Heating performance data to EN 14511 (A−7/W35)
Rated heating outputkW3.85.66.5
Power consumptionkW1.272.002.41
Coefficient of performance ε in heating mode (COP)3.02.82.7
Heating performance data to EN 14511 (A−7/W55)
Rated heating outputkW3.55.26.2
Power consumptionkW1.632.463.06
Coefficient of performance ε in heating mode (COP)2.22.12.0
Heating performance data to Commission Regulation (EU) No 813/2013 (average climatic conditions)
Low temperature application (W35)
Energy efficiency ηs%176180175
Rated heating output PratedkW4.05.56.5
Seasonal coefficient of performance (SCOP)4.54.64.4
Medium temperature application (W55)
Energy efficiency ηs%127141137
Rated heating output PratedkW3.85.16.2
Seasonal coefficient of performance (SCOP)3.33.63.5
Energy efficiency class to Commission Regulation (EU) No 813/2013
Heating, average climatic conditions – Low temperature application (W35) (D→A+++)A+++A+++A+++
Heating, average climatic conditions – Medium temperature application (W55) (D→A+++)A++A++A++
Cooling performance data to EN 14511 (A35/W7)
Rated cooling capacitykW2.63.03.4
Fan speedrpm
Power consumptionkW0.901.031.17
Coefficient of performance in cooling mode (EER)2.92.92.9
Output controlkW1.8 to 4.01.8 to 4.81.8 to 5.0
Cooling performance data, average climatic conditions (A35/W7)
Rated cooling capacity PratedkW3.03.64.4
Seasonal cooling energy efficiency ratio (SEER)3.83.94.0
Cooling performance data to EN 14511 (A35/W18)
Rated cooling capacitykW4.05.06.0
Fan speedrpm
Power consumptionkW0.851.141.54
Coefficient of performance in cooling mode (EER)4.74.43.9
Output controlkW3.2 to 4.03.2 to 5.53.2 to 6.7
Cooling performance data, average climatic conditions (A35/W18)
Rated cooling capacity PratedkW4.65.66.9
Seasonal cooling energy efficiency ratio (SEER)4.54.74.9
Air inlet temperature
Cooling mode – Min.°C151515
Cooling mode – Max.°C454545
Heating mode – Min.°C−20−20−20
Heating mode – Max.°C404040
Heating water (secondary circuit)
Capacity excl. expansion vessell181818
Heat pump circuit minimum flow rate (defrosting)l/h100010001000
Max. flow temperature°C707070
Outdoor unit electrical values
Rated voltage1/N/PE 230 V~/50 Hz
Max. operating currentA1515.516
Cos φ0.990.990.99
Compressor starting current, inverter controlledA< 10< 10< 10
Compressor starting current with stalled armatureA< 10< 10< 10
Fuse protectionB16AB16AB16A
IP ratingIPX4IPX4IPX4
Indoor unit electrical values
PCB – Rated voltage1/N/PE 230 V~/50 Hz
PCB – Power supply fuse protection1 x B16A
PCB – Internal fuse protection6.3 A H (slow)/250 V~
Instantaneous heating water heater – Heating output (Max.)kW8
Instantaneous heating water heater – Stage 1kW2.4
Instantaneous heating water heater – Stage 2kW2.4
Instantaneous heating water heater – Stage 3kW3.2
400 V~ power supply fuse protection1 x B16A, 3-pole
Power supply fuse protection3 x B16A
Electrical values for indoor unit with central mains connection
PCB – Rated voltage1/N/PE 230 V~/50 Hz
PCB – Internal fuse protection6.3 A H (slow)/250 V~
Instantaneous heating water heater – Heating outputkW5
Power supply – Rated voltage1/N/PE 230 V~/50 Hz
Power supply – Fuse protection1 x B32A, 1-pole
Max. power consumption
Outdoor unit – FanW140140140
Outdoor unit – TotalkW2.33.63.7
Indoor unit – Integral secondary pump/heating circuit pump, heating/cooling circuit 1 (PWM)W636363
Indoor unit – Energy efficiency index EEI of the circulation pumps≤ 0.2≤ 0.2≤ 0.2
Indoor unit – Control unit/PCBW555
Indoor unit – Max. connected load, 230 V~ function componentsW100010001000
Mobile data transfer
WiFi – Transmission standardIEEE 802.11 b/g/n
WiFi – Frequency bandMHz2400 to 2483.5
WiFi – Max. transmission powerdBm+15
Low power radio – Transmission standardIEEE 802.15.4
Low power radio – Frequency bandMHz2400 to 2483.5
Low power radio – Max. transmission powerdBm+6
Refrigerant circuit
RefrigerantR290R290R290
Safety groupA3A3A3
Charge weightkg1.21.21.2
Global warming potential (GWP)0.020.020.02
CO2 equivalentt0.0000240.0000240.000024
Oil in compressorTypeHAF68HAF68HAF68
Oil volume in compressorl0.840 ±0.0200.840 ±0.0200.840 ±0.020
Outdoor unit dimensions
Total lengthmm600600600
Total widthmm114411441144
Total heightmm841841841
Indoor unit dimensions
Total lengthmm360360360
Total widthmm450450450
Total heightmm920920920
Total weight
Indoor unit – Emptykg474747
Indoor unit – Filled (max.)kg757575
Outdoor unitkg162162162
Connections to indoor unit without installation aid
Heating water flow/return, heating/cooling circuits or external buffer cylindermmCu 28 x 1.0Cu 28 x 1.0Cu 28 x 1.0
Heating water flow/return, DHW cylindermmCu 22 x 1.0Cu 22 x 1.0Cu 22 x 1.0
Heating water flow/return, outdoor unitmmCu 28 x 1.0Cu 28 x 1.0Cu 28 x 1.0


Viessmann Energy Management
  • Viessmann Energy Management is integrated in all heat pumps and in photovoltaic inverters/power storage systems with Viessmann One Base.
  • Energy Management allows balanced operation of components in the home which generate, consume or store electricity.
  • Its focus is on self-consumption optimisation of self-generated power from photovoltaic systems.
  • The energy management system provides extensive information on electricity flows and CO2 reduction
  • Viessmann Energy Management turns a heat pump with Viessmann One Base into a control centre for the energy flows in the home.
  • The energy flows between photovoltaics, heat pump, energy store, wallbox and other compatible accessories are optimised.
  • On request, customers can add further optimisation stages in the ViCare app.

For further information on system requirements, functions and use see Viessmann Energy Management and Viessmann One Base

Vitocal 150-A Standard (A04 230V V 105) 4kW Buying into Viessmann.

Viessmann use their best endeavours to ensure that their products are manufactured without any manufacturing or material defects.
The standard terms and conditions guarantee that Viessmann will fix or replace any manufacturing or material defects free of charge within a period of 2 years from the date of delivery.

For a fee the warranty may be extended to 7 years - Details

Viessmann Warranty Overview

Vitocal 150-A Standard (A04 230V V 105) 4kWReturn of Goods.

We very much hope you will be happy with your products, however we do understand items sometimes need to be returned.
Condition is all important, an item should have been treated in the same way as if it was on sale in a shop, unopened and unused with seals intact.
Large palleted items (boilers, heat pumps, cylinders etc.) must be returned as delivered, strapped and wrapped to the pallet, unopened.
Cylinders must be strapped as delivered in an upright position.

Policy.

Our returns policy can be found here.

We have placed cookies on your device to help make this website better.

Your Basket