Vitocal 150-A Compact (A10 230V V 109) 10kW

£15,927.60 inc VAT
1 In Stock

Vitocal 150-A Compact (A10 230V V 109) 10kW

The Vitocal 150-A Compact model has an integrated 190-litre DHW cylinder made of steel with Ceraprotect enamelling.

Up to 70 °C flow temperature

Heat pump with electric drive in monoblock design with outdoor and indoor unit.

Quick facts

  • Monobloc heat pump: indoor + outdoor unit
  • For space heating/cooling and domestic hot water heating
  • Up to 70 °C flow temperature (subject to system design)
  • With integral 190 litre DHW cylinder
  • Natural refrigerant R290 (low GWP)
  • Integral WiFi; system monitoring via ViCare (end user) and ViGuide (installer)

Product features – for space heating, cooling and domestic hot water (DHW) storage

  • For space heating, cooling and domestic hot water (DHW) heating
  • Monobloc indoor unit with heat pump control unit
  • Integral 190 litre DHW cylinder
  • High-efficiency circulation pump for the secondary circuit
  • Integral 4/3-way valve and safety assembly
  • Integral instantaneous heating water heater
  • Integral buffer cylinder and overflow valve
  • (li)integral fan ring heater and electric ribbon heater for the condensate pan

Advantages at a glance – high COP, up to 70 °C flow temp, R290, quiet operation
  • Low running costs thanks to high COP (coefficient of performance) to EN 14511: up to 5.2 at A7/W35 (depending on operating conditions)
  • Output control and DC inverter for high efficiency in partial load operation
  • Maximum flow temperature of up to 70 °C at an outside temperature of −10 °C (subject to system design)
  • Self-optimising control of the flow rate via Viessmann Hydro AutoControl
  • Environmentally responsible, natural refrigerant R290 with a particularly low GWP (global warming potential)
  • Convenient reversible design for heating and cooling (availability subject to system configuration)
  • Reduced sound emissions thanks to Advanced Acoustic Design (AAD)
  • Web-enabled via integral WiFi
  • Guided commissioning via ViGuide
  • Individual room control with components from ViCare Smart Climate

Key specifications - permissible operating pressure (heating water): 3 bar (0.3 MPa)
  • Permissible operating pressure (heating water): 3 bar (0.3 MPa)
  • Colour of indoor unit: Vitopearlwhite
  • Colour of outdoor unit: Vitosilver

Heat pump control unit - for weather-compensated mode
  • 7-inch colour touchscreen with energy cockpit
  • WiFi hotspot for local service without internet connection
  • Internet connection via WiFi
  • Control of a DHW circulation pump
  • Control of an instantaneous heating water heater
  • Active cooling control function
  • Integral energy statement
  • Setting of low-noise mode for the outdoor unit
  • Optimised energy management, e.g. in conjunction with photovoltaic system, power storage system
  • Display of energy flows in the ViCare app and ViGuide

Mobile applications - Communication technology

ViCare app – mobile application for system users
  • Mobile operation of the heating system for room heating and DHW heating, power storage units and ventilation systems
  • Assistance functions and fault display with option for direct connection to the contractor for service requests
  • For more information on system requirements and ViCare app registration and usage, see Vicare App Guide
  • Download:

Vitocal 150-A Compact (A10 230V V 109) 10kW   Vitocal 150-A Compact (A10 230V V 109) 10kW

ViGuide – mobile applications for trade partners
  • Service and maintenance with ViGuide for optimising workflows in operation, for the Viessmann trade partner
  • Ensures customer-friendly online services for the system user, provided they have enabled service via the ViCare app
  • Straightforward and efficient commissioning of heat generators with integral communication module, power storage units and ventilation systems, performed by heating contractors using ViGuide
  • In addition to the free version, ViGuide Plus and ViGuide Pro are also available as paid-for versions with additional analysis, remote maintenance and optimisation functions
  • For more information on system requirements and ViGuide registration and usage, see ViGuide App Guide
  • Download:

Vitocal 150-A Compact (A10 230V V 109) 10kW   Vitocal 150-A Compact (A10 230V V 109) 10kW

Standard delivery - Indoor and Outdoor units

IDU-A Compact indoor unit

  • Integral 4/3-way valve for room heating, DHW heating and bypass
  • (li)Integral steel DHW cylinder with Ceraprotect enamel coating, protected from corrosion by a protective magnesium anode, with thermal insulation
  • Integral high-efficiency circulation pump for the secondary circuit
  • Integral instantaneous heating water heater
  • Integral 16 l buffer cylinder
  • Integral safety valve and digital pressure gauge
  • Weather-compensated heat pump control unit with outside temperature sensor
  • Flow rate capturing
  • 18 l diaphragm expansion vessel

ODU 150-A outdoor unit

  • Inverter-controlled compressor
  • 4-way diverter valve
  • Electronic expansion valve
  • Evaporator and condenser
  • EC fan
  • Factory-filled with refrigerant R290
  • Heating water filter upstream of condenser
  • Transport aid for outdoor unit
  • Integral fan ring heater and electric ribbon heater for the condensate pan

Important

  • Specifications and features may vary by model and configuration. All performance figures are subject to system design, installation conditions and operating parameters.
  • A Basic or Comfort pre-plumbing jig and connectiopn set must be added to the order; see Accessories tab.
  • The heat pumps must be commissioned by Viessmann Technical Service or a specialist heat pump contractor trained by Viessmann.
  • To operate multiple regulated heating/cooling circuits downstream of the heating water buffer cylinder, a separate heating/cooling water buffer cylinder is required.
  • Extensions/accessories are required for the heating/cooling circuits with mixer and optimisation of self-consumption: see Accessories tab.

Vitocal 150-A Compact – Specification Table

To verify, always consult the latest manufacturer’s documentation.

Heat pumps with 230 V~ outdoor unit – Sizes 10 / 13 / 16

Item Unit 10 13 16
Heating performance data to EN 14511 (A2/W35)
Rated heating outputkW5.86.77.6
Fan speedrpm
Power consumptionkW1.411.762.00
Coefficient of performance ε in heating mode (COP)4.13.83.8
Output controlkW2.2 to 11.02.6 to 12.33.0 to 13.7
Heating performance data to EN 14511 (A7/W35, 5 K spread)
Rated heating outputkW7.38.19.1
Fan speedrpm430440450
Air flow ratem³/h404541884331
Power consumptionkW1.461.621.86
Coefficient of performance ε in heating mode (COP)5.05.04.9
Output controlkW2.6 to 12.03.0 to 13.43.3 to 14.9
Heating performance data to EN 14511 (A−7/W35)
Rated heating outputkW10.011.112.4
Power consumptionkW3.233.874.39
Coefficient of performance ε in heating mode (COP)3.02.872.82
Heating performance data to EN 14511 (A−7/W55)
Rated heating outputkW9.210.611.8
Power consumptionkW4.795.125.28
Coefficient of performance ε in heating mode (COP)1.92.12.2
Heating performance data to Commission Regulation (EU) No 813/2013 (average climatic conditions)
Low temperature application (W35)
Energy efficiency ηs%190178178
Rated heating output PratedkW9.812.413.67
Seasonal coefficient of performance (SCOP)4.8254.524.525
Medium temperature application (W55)
Energy efficiency ηs%145141141
Rated heating output PratedkW9.3712.113.37
Seasonal coefficient of performance (SCOP)3.73.63.6
DHW heating energy efficiency ηwh (EN 16147:2017+A1:2022)%109109109
Energy efficiency class to Commission Regulation (EU) No 813/2013
Heating, average climatic conditions – Low temperature application (W35) (D→A+++)A+++A+++A+++
Heating, average climatic conditions – Medium temperature application (W55) (D→A+++)A++A++A++
DHW heating, draw-off profile (XL) (F→A+)AAA
Cooling performance data to EN 14511 (A35/W7)
Rated cooling capacitykW3.95.66.3
Fan speedrpm550550550
Power consumptionkW1.181.651.85
Coefficient of performance in cooling mode (EER)3.33.43.4
Output controlkW3.9 to 7.24.2 to 8.04.5 to 8.7
Cooling performance data, average climatic conditions (A35/W7)
Rated cooling capacity PratedkW6.98.118.93
Seasonal cooling energy efficiency ratio (SEER)3.63.84.1
Cooling performance data to EN 14511 (A35/W18)
Rated cooling capacitykW9.611.013.2
Fan speedrpm550550550
Power consumptionkW2.182.753.62
Coefficient of performance in cooling mode (EER)4.44.03.7
Output controlkW6.3 to 14.46.6 to 15.76.9 to 17.0
Cooling performance data, average climatic conditions (A35/W18)
Rated cooling capacity PratedkW9.8111.5113.32
Seasonal cooling energy efficiency ratio (SEER)7.26.76.3
Air inlet temperature
Cooling mode – Min.°C151515
Cooling mode – Max.°C454545
Heating mode – Min.°C−20−20−20
Heating mode – Max.°C404040
Heating water (secondary circuit)
Capacity excl. expansion vessell181818
Heat pump circuit minimum flow rate (defrosting)l/h100010001000
Max. flow temperature°C707070
Outdoor unit electrical values
Rated voltage, compressor1/N/PE 230 V~/50 Hz
Max. operating current, compressorA202325
Cos φ0.990.990.99
Compressor starting current, inverter controlledA< 10< 10< 10
Compressor starting current with stalled armatureA< 10< 10< 10
Fuse protectionAB25AB25AB25A
IP ratingIPX4IPX4IPX4
Indoor unit electrical values
PCB – Rated voltage1/N/PE 230 V~/50 Hz
PCB – Power supply fuse protection1 x B16A
PCB – Internal fuse protection6.3 A H (slow)/250 V~
Instantaneous heating water heater – Heating output (Max.)kW8
Instantaneous heating water heater – Stage 1kW2.4
Instantaneous heating water heater – Stage 2kW2.4
Instantaneous heating water heater – Stage 3kW3.2
400 V~ power supply fuse protection1 x B16A, 3-pole
Power supply fuse protection3 x B16A
Electrical values for indoor unit with central mains connection
PCB – Rated voltage1/N/PE 230 V~/50 Hz
PCB – Internal fuse protection6.3 A H (slow)/250 V~
Instantaneous heating water heater – Heating outputkW5
Power supply – Rated voltage1/N/PE 230 V~/50 Hz
Power supply – Fuse protection1 x B32A, 1-pole
Max. power consumption
Outdoor unit – FanW2 x 1402 x 1402 x 140
Outdoor unit – TotalkW4.555.45.4
Indoor unit – Integral secondary pump/heating circuit pump, heating/cooling circuit 1 (PWM)W636363
Indoor unit – Energy efficiency index EEI of the circulation pump≤ 0.2≤ 0.2≤ 0.2
Indoor unit – Control unit/PCBW555
Indoor unit – Max. connected load, 230 V~ function componentsW100010001000
Mobile data transfer
WiFi – Transmission standardIEEE 802.11 b/g/n
WiFi – Frequency bandMHz2400 to 2483.5
WiFi – Max. transmission powerdBm+15
Low power radio – Transmission standardIEEE 802.15.4
Low power radio – Frequency bandMHz2400 to 2483.5
Low power radio – Max. transmission powerdBm+6
Refrigerant circuit
RefrigerantR290R290R290
Safety groupA3A3A3
Charge weightkg222
Global warming potential (GWP)0.020.020.02
CO2 equivalentt0.000040.000040.00004
Compressor (hermetically sealed)Twin rotary
Oil in compressorTypeHAF68HAF68HAF68
Oil volume in compressorl1.150 ±0.0201.150 ±0.0201.150 ±0.020
Permissible operating pressure
High pressure sidebar30.330.330.3
High pressure sideMPa3.033.033.03
Low pressure sidebar30.330.330.3
Low pressure sideMPa3.033.033.03
Integral DHW cylinder
Capacityl190190190
Max. draw-off volume at mixed water temperature 40 °C (V40) with specified set cylinder temperaturel (°C)256 (51)256 (51)256 (51)
Max. DHW temperature°C686868
Outdoor unit dimensions
Total lengthmm600600600
Total widthmm114411441144
Total heightmm138213821382
Indoor unit dimensions
Total lengthmm597597597
Total widthmm600600600
Total heightmm190019001900
Total weight
Indoor unit – Emptykg170170170
Indoor unit – Filled (max.)kg386386386
Outdoor unitkg191191191
Permissible operating pressure, secondary side
Heating waterbar333
Heating waterMPa0.30.30.3
DHWbar101010
DHWMPa1.01.01.0
Connections to indoor unit without connection set/installation aid
Heating water flow/return, heating circuits or heating water buffer cylindermmCu 28 x 1.0Cu 28 x 1.0Cu 28 x 1.0
Heating water flow/return, DHW cylindermmCu 22 x 1.0Cu 22 x 1.0Cu 22 x 1.0
Heating water flow/return, outdoor unitmmCu 28 x 1.0Cu 28 x 1.0Cu 28 x 1.0
Length of connection line, indoor – outdoor unit (e.g. Quattro connection line)
Length of connection linem5 to 205 to 205 to 20
Sound power at rated heating output (ErP)
Indoor unit – ErPdB(A)404040
Outdoor unit – ErPdB(A)565859
Outdoor unit – Max.dB(A)606263
Outdoor unit – Low-noise mode, stage 2dB(A)525252


Viessmann Energy Management
  • Viessmann Energy Management is integrated in all heat pumps and in photovoltaic inverters/power storage systems with Viessmann One Base.
  • Energy Management allows balanced operation of components in the home which generate, consume or store electricity.
  • Its focus is on self-consumption optimisation of self-generated power from photovoltaic systems.
  • The energy management system provides extensive information on electricity flows and CO2 reduction
  • Viessmann Energy Management turns a heat pump with Viessmann One Base into a control centre for the energy flows in the home.
  • The energy flows between photovoltaics, heat pump, energy store, wallbox and other compatible accessories are optimised.
  • On request, customers can add further optimisation stages in the ViCare app.


For further information on system requirements, functions and use see Viessmann Energy Management and Viessmann One Base

Vitocal 150-A Compact (A10 230V V 109) 10kW Buying into Viessmann.

Viessmann use their best endeavours to ensure that their products are manufactured without any manufacturing or material defects.
The standard terms and conditions guarantee that Viessmann will fix or replace any manufacturing or material defects free of charge within a period of 2 years from the date of delivery.

For a fee the warranty may be extended to 7 years - Details

Viessmann Warranty Overview

Vitocal 150-A Compact (A10 230V V 109) 10kWReturn of Goods.

We very much hope you will be happy with your products, however we do understand items sometimes need to be returned.
Condition is all important, an item should have been treated in the same way as if it was on sale in a shop, unopened and unused with seals intact.
Large palleted items (boilers, heat pumps, cylinders etc.) must be returned as delivered, strapped and wrapped to the pallet, unopened.
Cylinders must be strapped as delivered in an upright position.

Policy.

Our returns policy can be found here.

We have placed cookies on your device to help make this website better.

Your Basket